Kluczowe parametry
-
Measured variables
CH4, CO, CO2, Corg, HCl, HF, H2O, NH3, NO, NO2, N2O, O2, SO2, NOx, C3H8, C2H6
-
Ambient temperature range
+5 °C ... +35 °C
With cooling device:+5 °C ... +50 °C -
Process temperature
≤ +1,300 °C
Zastosowanie
The FTIR measurement principle enables the simultaneous acquisition of more than 12 measuring components. The MCS100FT FTIR analyzer system with its heated measuring cell made of corrosion-resistant material also enables monitoring of hydrogen fluoride limits as required by legislation. With its reliable measurement technology, easy operation, and low maintenance requirements, the MCS100FT provides a hassle-free solution concept that offers unequaled opportunities.
Emission monitoring in waste incineration plants
Reliable HF limit value monitoring
Monitoring of gaseous emissions in cement or power plants
Device properties:
Small suitability-tested HF measuring range: 0 ... 3 mg/m³
Automatic spectrum adjustment via AutoVAL for reliable measured values
Suitability-tested according to EN15267
Remote control and diagnosis via SOPAS ET software
Automatic adjustment of the analyzer
Automatic backwashing and filter cleaning of the extraction unit
Korzyści
Reliable HF limit value monitoring
Just one analyzer for over 12 measuring components
Easy integration into the customer network environment
Long 6-month maintenance interval for many measuring components
Suitability-tested measurement of greenhouse gases such as N2O, CH4 and CO2
Low maintenance effort
Segment Xpert
-
Produkty specjalistyczne
- Zaprojektowane z myślą o wymagających procesach
Poziom zaawansowania
Prostota obsługi
Zależna od urządzenia

-
Produkty podstawowe
- Łatwe w doborze, montażu i obsłudze
Poziom zaawansowania
Prostota obsługi
-
Produkty standardowe
- Niezawodne, wytrzymałe i łatwe w utrzymaniu
Poziom zaawansowania
Prostota obsługi
-
Produkty zaawansowane
- Wysoka funkcjonalność i wygoda użytkowania
Poziom zaawansowania
Prostota obsługi
-
Produkty specjalistyczne
- Zaprojektowane z myślą o wymagających procesach
Poziom zaawansowania
Prostota obsługi
Zależna od urządzenia
Segmentacja FLEX | Poziom zaawansowania | Prostota obsługi |
---|---|---|
Segment Fundamental Zaspokoi Twoje podstawowe potrzeby pomiarowe |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Lean Z łatwością obsłuży Twoje codzienne procesy |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Extended Zoptymalizuje Twoje procesy dzięki innowacyjnym technologiom |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Xpert Sprosta Twoim najbardziej wymagającym pomiarom |
Poziom zaawansowania
|
Prostota obsługi
Zależna od urządzenia |
-
Zasada pomiaru
FTIR spectroscopy, flame ionisation detection, Zirconium dioxide sensor
-
Measured variables
CH4, CO, CO2, Corg, HCl, HF, H2O, NH3, NO, NO2, N2O, O2, SO2, NOx, C3H8, C2H6
-
Performance-tested measurands
CH4, CO, CO2, Corg, HCl, HF, H2O, NH3, NO, NO2, N2O, O2, SO2
-
Measuring range
CH4: 0 ... 70 ppm / 0 ... 210 ppm
SO2: 0 ... 25 ppm / 0 ... 525 ppm
NOx: 0 ... 100 ppm / 0 ... 1,000 ppm
C3H8: 0 ... 25 ppm
CO: 0 ... 60 ppm / 0 ... 1,200 ppm
CO2: 0 ... 25 Vol.-%
Corg: 0 ... 7.5 ppm / 0 ... 75 ppm
HCl: 0 ... 10 ppm / 0 ... 100 ppm
HF: 0 ... 3 ppm / 0 ... 10 ppm
H2O: 0 ... 40 Vol.-%
NH3: 0 ... 13 ppm / 0 ... 65 ppm
NO: 0 ... 150 ppm / 0 ... 1,500 ppm
NO2: 0 ... 25 ppm / 0 ... 250 ppm
N2O: 0 ... 25 ppm / 0 ... 250 ppm
O2: 0 ... 21 Vol.-%
C2H6: 0 ... 40 ppm
Other measuring ranges and components on request -
Process temperature
≤ +1,300 °C
-
Process pressure
900 hPa ... 1,100 hPa
-
Ambient temperature range
+5 °C ... +35 °C
With cooling device:+5 °C ... +50 °C -
Ambient humidity
≤ 80 %
Non-condensing -
Conformities
Approved for plants requiring approval:
2001/80/EC (13. BImSchV)
2000/76/EC (17. BImSchV)
27. BImSchV
TA-Luft (Prevention of Air Pollution)
EN 15267
EN 14181
MCERTS -
Degree of protection
IP43
Optional: IP54 -
Product safety
CE
-
-
Instrukcja obsługi (BA)
SFU
-
Instrukcja obsługi (BA)
Wersja angielska - 01/2025Gas Sampling Unit
EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
2.6 MB
Nazwa pliku:
8029819_YJ80_OI_SFU_IP23_en_V3-0_2015-08_EHS.pdf
-
-
-
Instrukcja obsługi (BA)
SFU weatherproof enclosure
-
Instrukcja obsługi (BA)
Wersja angielska - 01/2025Gas Sampling Unit with Weatherproof Enclosure
EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
2.6 MB
Nazwa pliku:
8029817_14SF_OI_SFU_IP54_en_V1-1_2019-07_EHS.pdf
-
-
-
Instrukcja obsługi (BA)
MCS100FT
-
Instrukcja obsługi (BA)
Wersja angielska - 01/2025FTIR Multicomponent Analysis System for Continuous Flue Gas Monitoring
EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
3.6 MB
Nazwa pliku:
8029896_1K96_OI_MCS100FT_en_V2-2_2023-11_EHS.pdf
-
-
-
Rozwiązania branżowe (SO)
Solutions for waste-to-energy plants
-
Rozwiązania branżowe (SO)
Wersja angielska - 01/2025Endress+Hauser offers ideal automation and safety solutions for collection, sorting and recycling of waste.
Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
2.4 MB
Nazwa pliku:
8030416_SO_Waste_en_V1-0_2025.01_EHS.pdf
-
-
-
Broszura dot. kompetencji (CP)
Emission Monitoring Solutions – broad instrument portfolio and longstanding experience
-
Broszura dot. kompetencji (CP)
Wersja angielska - 01/2025An overview brochure about emission monitoring, their measuring
principles and technologies, global requirements and services, a
selection guide and the measuring devices at a glanceJęzyk:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
4.5 MB
Nazwa pliku:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
-
-
-
Broszura nt. innowacji (IN)
MCS100FT – FTIR analyzer system
-
Broszura nt. innowacji (IN)
Wersja angielska - 01/2025With one FTIR analyzer system for providing complete and continuous emission monitoring
Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
2.6 MB
Nazwa pliku:
8029954_IN_MCS100FT_en_V4-0_2025.01_EHS.pdf
-
-
-
Plik DTM do weryfikacji
MCS100FT SDD file
-
Plik DTM do weryfikacji
Wersja - YHR2SOPAS device description file for MCS100FT
Język:
Language neutral
Wersja:
18/12/2014
Rozmiar pliku:
18 MB
Nazwa pliku:
MCS100FT SDD file
-
-
-
Plik DTM do weryfikacji
MCS100FT, FID100FT SDD file
-
Plik DTM do weryfikacji
Wersja - YNO0SOPAS device description file for MCS100FT, FID100FT
Język:
Language neutral
Wersja:
25/11/2015
Rozmiar pliku:
458 KB
Nazwa pliku:
MCS100FT, FID100FT SDD file
-
Wybierz jedną z zaproponowanych przez nas opcji
-
-- selected coding-- selected label99.999,00<%label%>
-
Szukasz jeszcze innych opcji? Aby kontynuować, użyj indywidualnego konfiguratora .
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Szukasz jeszcze innych opcji? Aby kontynuować, użyj indywidualnego konfiguratora .
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Rysunki CAD Rysunki CAD
- Rysunki CAD
-
Cena za sztukę
-
<%range%><%price%>
-
- Opcjonalne dodatki