The MCS200HW is a analyzer system for continuous monitoring of up to 10 IR measurement components in flue gases. All parts which touch media are heated above the dew point and therefore protected from corrosion. Internal reference point monitoring allows for a quick check of the measured values without test gases. The web display and the task assistant integrated in the software makes operation very easy. MCS200HW Ex allows reliable emission measurement even in explosion-hazardous areas.
Emission monitoring for waste incineration plants as well as power plants and plants with co-incineration, e.g. cement plants
Measurement of nitrogen oxides in nitric acid plants
Device properties:
Measurement of up to 10 IR components plus O2 and TOC
Wear-free gas distribution through ejector pumps
Reference point monitoring with internal calibration cells
Web server for platform-independent device control
Use of dry test gases for HCl and NH3
Classification for ATEX Zone 2, IIC T3 gb
Korzyści
Only one analyzer necessary for simultaneous monitoring of up to 12 gas components
Convenient, task-oriented operation
Remote access without additional software
High availability due to certified internal third-party monitoring (QAL3) without test gases
Data transmission possible via just one interface
Use in explosion-hazardous areas thanks to rugged, pressurized housing
CH4: 0 to 50 mg/m³ / 0 to 500 mg/m³ CO: 0 to 75 mg/m³ / 0 to 10,000 mg/m³ CO2: 0 to 25% by vol. Corg: 0 to 15 mg/m³ / 0 to 50 mg/m³ / 0 to 150 mg/m³ / 0 to 500 mg/m³ HCl: 0 to 15 mg/m³ / 0 to 3,000 mg/m³ H2O: 0 to 40% by vol. NH3: 0 to 10 mg/m³ / 0 to 500 mg/m³ NO: 0 to 150 mg/m³ / 0 to 2,500 mg/m³ NO2: 0 to 50 mg/m³ / 0 to 500 mg/m³ N2O: 0 to 100 mg/m³ / 0 to 2,000 mg/m³ O2: 0 to 25% by vol. SO2: 0 to 75 mg/m³ / 0 to 2,500 mg/m³
Process temperature
≤ +550 °C
Process pressure
850 hPa ... 1,100 hPa
Ambient temperature range
+5 °C ... +50 °C
Ambient humidity
≤ 90 % Relative humidity; non-condensing
Conformities
Approved for plants requiring approval 2000/76/EC (17. BImSchV) 2001/80/EC (13. BImSchV) 27. BImSchV EN 15267 EN 14181
Hazardous area approvals
MCS200HW Ex: ATEX: II 3G Ex dc ec ic [ic] mc nC pzc IIC T3 Gc Analyzer cabinet
Proven measuring technology for flue gas monitoring
as standard analyzer cabinet as well as an Ex version;
ready for current and future emission regulations.
Multi component analyzer system, ready for current and future
emission regulations; for flue gas monitoring as standard analyzer
cabinet as well as an Ex version
Emission Monitoring Solutions – broad instrument portfolio and
longstanding experience
Broszura dot. kompetencji (CP)
Wersja angielska - 01/2025
New version available in English
An overview brochure about emission monitoring, their measuring principles and technologies, global requirements and services, a selection guide and the measuring devices at a glance
Multi component analyzer system, ready for current and future emission regulations; for flue gas monitoring as standard analyzer cabinet as well as an Ex version
Proven measuring technology for flue gas monitoring as standard analyzer cabinet as well as an Ex version; ready for current and future emission regulations.
Kontynuuj wybór z uwzględnieniem wszystkich możliwych opcji
Szanujemy Państwa prywatność
Używamy plików cookie, aby poprawić komfort przeglądania, gromadzić dane statystyczne w celu optymalnego działania witryny i wyświetlać spersonalizowane reklamy lub treści.
Wybierając "Akceptuj wszystko", wyrażacie Państwo zgodę na używanie plików cookie.
Aby uzyskać więcej informacji, prosimy o zapoznanie się z naszą Polityką plików cookie .