Przepływomierz Coriolisa Proline Promass E 200

Proline Promass E 200 / 8E2B

8E2B
Please Wait (spinning wheel)
Ładowanie
Ceny tymczasowo niedostępne
Price on request
aktywacja ceny
cena: podaj informacje
from CHF ??.-
Filtruj pomiar / zastosowanie
Pomiar / Zastosowanie

Skonfiguruj, aby pobrać rysunki CAD dla tego produktu

  • Product headline

    Genuine loop-powered flowmeter for minimized cost of ownership.
    Accurate measurement of liquids and gases for a wide range of standard applications.

  • Sensor features

    Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Compact dual-tube sensor. std_successorproducts_product_differentiating_tech_features_7694_1530102815. Process pressure up to 100 bar (1450 psi).

  • Transmitter features

    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
    Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

  • Średnica nominalna

    DN 8 to 50 (⅜ to 2")

  • Materiały w kontakcie z medium

    Measuring tube: 1.4539 (904L)
    Connection: 1.4404 (316/316L)

  • Wielkości mierzone

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density

  • Maksymalny błąd pomiaru

    Mass flow (liquid): ±0.25 %
    Volume flow (liquid): ±0.25 %
    Mass flow (gas): ±0.75 %
    Density (liquid): ±0.0005 g/cm³

  • Zakres pomiarowy

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Maks. ciśnienie procesu

    PN 100, Class 600, 63K

  • Zakres temperatury medium

    –40 to +140 °C (–40 to +284 °F)

  • Temperatura otoczenia

    –40 to +60 °C (–40 to +140 °F)

  • Materiał obudowy czujnika

    1.4301 (304), corrosion resistant

  • Materiał obudowy przetwornika

    AlSi10Mg, coated

  • Stopień ochrony

    IP66/67, type 4X enclosure

  • Wyświetlacz

    4‐line backlit display with touch control
    (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Wyjścia

    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

  • Wejścia

    None

  • Komunikacja cyfrowa

    HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Zasilacz

    DC 18 to 35 V (4‐20 mA HART with/without
    pulse/frequency/switch)
    DC 18 to 30 V (20 mA HART, 4‐20 mA)
    DC 9 to 32 V (PROFIBUS PA)

  • Dopuszczenia do stosowania w strefach zagrożonych wybuchem

    ATEX, IECEx, cCSAus, NEPSI, INMETRO

  • Inne certyfikaty i dopuszczenia

    3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, PED, CRN, 3-A

  • Product safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    PED, CRN

  • Material certificates

    3.1 material

  • Hygienic approvals and certificates

    3-A

  • Product headline

    Genuine loop-powered flowmeter for minimized cost of ownership.
    Accurate measurement of liquids and gases for a wide range of standard applications.

  • Sensor features

    Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
    Compact dual-tube sensor. std_successorproducts_product_differentiating_tech_features_7694_1530102815. Process pressure up to 100 bar (1450 psi).

  • Transmitter features

    Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology.
    Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).

  • Średnica nominalna

    DN 8 to 50 (⅜ to 2")

  • Materiały w kontakcie z medium

    Measuring tube: 1.4539 (904L)
    Connection: 1.4404 (316/316L)

  • Wielkości mierzone

    Mass flow, density, temperature, volume flow, corrected volume flow, reference density

  • Maksymalny błąd pomiaru

    Mass flow (liquid): ±0.25 %
    Volume flow (liquid): ±0.25 %
    Mass flow (gas): ±0.75 %
    Density (liquid): ±0.0005 g/cm³

  • Zakres pomiarowy

    0 to 70 000 kg/h (0 to 2570 lb/min)

  • Maks. ciśnienie procesu

    PN 100, Class 600, 63K

  • Zakres temperatury medium

    –40 to +140 °C (–40 to +284 °F)

  • Temperatura otoczenia

    –40 to +60 °C (–40 to +140 °F)

  • Materiał obudowy czujnika

    1.4301 (304), corrosion resistant

  • Materiał obudowy przetwornika

    AlSi10Mg, coated, 1.4404 (316L)

  • Stopień ochrony

    IP66/67, type 4X enclosure

  • Wyświetlacz

    4‐line backlit display with touch control
    (operation from outside)
    Configuration via local display and operating tools possible
    Remote display available

  • Wyjścia

    4‐20 mA HART (passive)
    4‐20 mA (passive)
    Pulse/frequency/switch output (passive)

  • Wejścia

    None

  • Komunikacja cyfrowa

    HART, PROFIBUS PA, FOUNDATION Fieldbus

  • Zasilacz

    DC 18 to 35 V (4‐20 mA HART with/without
    pulse/frequency/switch)
    DC 18 to 30 V (20 mA HART, 4‐20 mA)
    DC 9 to 32 V (PROFIBUS PA)

  • Dopuszczenia do stosowania w strefach zagrożonych wybuchem

    ATEX, IECEx, cCSAus, NEPSI, INMETRO

  • Product safety

    CE, C-Tick, EAC marking

  • Functional safety

    Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)

  • Pressure approvals and certificates

    PED, CRN

  • Hygienic approvals and certificates

    3-A