The Batch Controller RA33 is designed to record flow and control output signals for valves and pumps to ensure the exact dosing of predefined batch quantities. The measured volume can be corrected with the temperature/density compensation function. The filling process can be optimized with an automatic or fixed after-run correction. Mineral oils can be corrected according to the ASTM D1250-04 standard.
Recording and controlling of slow batch operations with a duration of longer than 10 seconds. Typical applications include:
Food industry
Chemical industry
Pharmaceutical industry
Oil & gas industry
Korzyści
Fixed and automatic after-run correction for constant, extremely accurate results
Higher quality through fast and exact dosing
Optional volume correction for mineral oils as per ASTM D1250-04
Detailed logging of protocols (preset counter, volume counter, batch name and number) as well as error messages and changes of operating parameters
Standard models are suitable for connecting and supplying all common flow transmitters, temperature sensors and density sensors
Remote control option to start and abort batch runs
Daily, monthly and annual statistics on the batch run size and quantity
CIECH Sarzyna w latach 2010-2013 przeprowadziła inwestycję budowy instalacji produkcyjnej substancji MCPA i MCPP-P o wartości ponad 146 mln złotych. Endress+Hauser dostarczył urządzenia kontrolno-pomiarowe, spełniające wysokie wymagania branży chemicznej.
Low voltage power supply: 100 bis 230 V AC (-15% / +10%) Small voltage power supply: 24 V DC (-50% / +75%) 24 V AC (±50%)
Protection class
IP65
Typ sygnału wejściowego
1 x analogue (I) / pulse (for flow) 1 x RTD (for temperature) 1 x analogue (I) (for density) Loop power supply 24V DC (+/-16%)
Wyjście
1 x analogue (I) / pulse (active) 2 x open collector
Wymiary (S x W x G)
144 x 144 x 103.1 mm (5.67" x 5.67" x 4.06")
Działanie
3 operation buttons and 14 function buttons for batch operation or via FieldCare Read out of historical / logged data via Field Data Manager software (SQL database and visualization interface) Selectable language
Wyświetlacz
160 x 80 Dot-Matrix LCD with white backlit Colour change in case of alarm event Active display area 70 x 34 mm
Software functions
Volume calculation 1 or 2 stage operation Manual and automatic overrun correction Volume correction factor (VCF) according ASTM D1250-04 for generalized crude oils, refined products and lubricating oils
Soluciones para el lazo de control Indicadores, dispositivos de interfaz, protección contra sobretensiones, gestores de aplicaciones y energía, registradores sin papel y paquetes de software asociado para la automatización de procesos.
Lösungen zur Komplettierung der Messstelle Anzeiger, Interfacegeräte, Überspannungsschutz, Energie- und Applikationsmanager, Datenmanager, Bildschirmschreiber und Softwarepakete für die Prozessautomatisierung
Używamy plików cookie, aby poprawić komfort przeglądania, gromadzić dane statystyczne w celu optymalnego działania witryny i wyświetlać spersonalizowane reklamy lub treści.
Wybierając "Akceptuj wszystko", wyrażacie Państwo zgodę na używanie plików cookie.
Aby uzyskać więcej informacji, prosimy o zapoznanie się z naszą Polityką plików cookie .