"Produkt niedostępny"
Differential pressure, capacitive.
Transmitter.
Application: pressure, level, flow.
Membrane: ceramic.
Secondary process barrier.
:: High long term stability.
:: High reliability through process
monitoring.
:: High resistance to abrasion.
:: Enhanced mechanical integrity.
:: Modular.
Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Maksymalny błąd pomiaru
0,1%
Maks. ciśnienie procesu
max. 100 bar (max. 1.450 psi)
Zakres temperatury medium
Temperature gradient from pressure piping
Wyświetlacz
Option
Wyjścia
4 ... 20mA HART PROFIBUS PA FOUNDATION Fieldbus
Komunikacja cyfrowa
HART PROFIBUS PA Fondation Fieldbus
Dopuszczenia do stosowania w strefach zagrożonych wybuchem
ATEX FM CSA
Charakterystyka
Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Zasilanie / Komunikacja
4...20mA / HART: 11,5...45V DC Ex: 11,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC Ex: 9...24V DC
Błąd pomiaru
0,1%
Stabilność długoterminowa
0,1% of URL/year 0,25% of URL/5 years
Temperatura procesu
-40°C...85°C
Temperatura otoczenia
-40°C...85°C
Zakres pomiarowy
25mbar...3bar
Zakresowość
max. 100:1
Wartość graniczna nadciśnienia
100bar
Przyłącze technologiczne
1/4-18NPT RC1/4"
Wyjście
4 ... 20mA HART PROFIBUS PA FOUNDATION Fieldbus
Certyfikaty i dopuszczenia
ATEX FM CSA SIL WHG/overspill protection EN10204-3.1
Następca
PMD70
Product headline
Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Maksymalny błąd pomiaru
0,1%
Maks. ciśnienie procesu
max. 100 bar (max. 1.450 psi)
Zakres temperatury medium
Temperature gradient from pressure piping
Wyświetlacz
Option
Wyjścia
4 ... 20mA HART PROFIBUS PA FOUNDATION Fieldbus
Komunikacja cyfrowa
HART PROFIBUS PA Fondation Fieldbus
Dopuszczenia do stosowania w strefach zagrożonych wybuchem
ATEX FM CSA
Product headline
Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Maksymalny błąd pomiaru
0,1%
Maks. ciśnienie procesu
max. 100 bar (max. 1.450 psi)
Zakres temperatury medium
Temperature gradient from pressure piping
Wyświetlacz
Option
Wyjścia
4 ... 20mA HART PROFIBUS PA FOUNDATION Fieldbus
Komunikacja cyfrowa
HART PROFIBUS PA Fondation Fieldbus
Dopuszczenia do stosowania w strefach zagrożonych wybuchem
ATEX FM CSA
Charakterystyka / Aplikacja
Digital differential pressure transmitter, capacitive sensor with ceramic diaphragm Safety by function monitoring and membrane detection, modular transmitter design
Zasilanie / Komunikacja
4 ... 20 mA / HART: 11,5...45V DC Ex: 11,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC Ex: 9...24V DC
Błąd pomiaru
0,1%
Stabilność długoterminowa
0,1% of URL/year 0,25% of URL/5 years
Temperatura otoczenia
-40°C...85°C
Temperatura procesu
-40°C...85°C
Absolutne ciśnienie medium / Wartość graniczna nadciśnienia
100bar
Zakres ciśnienia mierzonego
25mbar...3bar
Główne części wchodzące w kontakt z medium
Alloy C 316L Monel Tantal
Przyłącze technologiczne
1/4-18NPT RC1/4"
Maks. odległość pomiarowa
30m H2O
Wyjście
4 ... 20 mA HART PROFIBUS PA FOUNDATION Fieldbus
Certyfikaty / Dopuszczenia
ATEX FM CSA SIL WHG/overspill protection EN10204-3.1
Karta katalogowa: Przetwornik ró¿nicy ci#nieñ Deltabar S PMD230/235, FMD230/630/633
Karta katalogowa (TI)
Wersja polska - 04/2000
New version available in English
Inteligentny przetwornik ró¿nicy ci#nieñ z odpornym na przeci¹¿enia, ceramicznym lub piezorezystancyjnym elementem pomiarowym i funkcjami monitoruj¹cymi. Protoko³y komunikacji: HART, PROFIBUS-PA, Foundation-Fieldbus.
Używamy plików cookie, aby poprawić komfort przeglądania, gromadzić dane statystyczne w celu optymalnego działania witryny i wyświetlać spersonalizowane reklamy lub treści.
Wybierając "Akceptuj wszystko", wyrażacie Państwo zgodę na używanie plików cookie.
Aby uzyskać więcej informacji, prosimy o zapoznanie się z naszą Polityką plików cookie .