Kluczowe parametry
-
Measuring range
More than 60 measuring components available (depending on concentration and sample gas composition)
Up to 6 components simultanously
2 measuring ranges per component
Automatic measuring range switching (adjaustable)
2 limit values per component
Measuring ranges depend on application and combination of measuring components
Zastosowanie
The MCS300P is an extractive process photometer for measuring gaseous or liquid media. It measures IR- and VIS-active components with variable measuring ranges from very low (ppm) to high (vol%) concentrations. For monitoring toxic or flammable mixtures, it features special process cells with integrated protective devices, such as double seals and purge gas chambers on both sides.
Process monitoring in production of vinyl chloride or isocyanate
Process control in the chemical industry
Process monitoring in the production of plastics
Monitoring of exhaust gas purification plants
Device properties:
Simultaneous measurement of up to 6 components
Process cells up to 60 bar and 200 °C available
Automated sample point switching
Protective devices for measurement of toxic or flammable mixtures
Extended operation via PC and SOPAS ET software
Flexible I/O module system
Korzyści
Automatic adjustment without expensive test gases
Integration into existing networks
Integration of external parameters like temperature or pressure
Suitable for explosive environments
Easy installation and maintenance thanks to transparent, compact design
Segment Xpert
-
Produkty specjalistyczne
- Zaprojektowane z myślą o wymagających procesach
Poziom zaawansowania
Prostota obsługi
Zależna od urządzenia
-
Produkty podstawowe
- Łatwe w doborze, montażu i obsłudze
Poziom zaawansowania
Prostota obsługi
-
Produkty standardowe
- Niezawodne, wytrzymałe i łatwe w utrzymaniu
Poziom zaawansowania
Prostota obsługi
-
Produkty zaawansowane
- Wysoka funkcjonalność i wygoda użytkowania
Poziom zaawansowania
Prostota obsługi
-
Produkty specjalistyczne
- Zaprojektowane z myślą o wymagających procesach
Poziom zaawansowania
Prostota obsługi
Zależna od urządzenia
Segmentacja FLEX | Poziom zaawansowania | Prostota obsługi |
---|---|---|
Segment Fundamental Zaspokoi Twoje podstawowe potrzeby pomiarowe |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Lean Z łatwością obsłuży Twoje codzienne procesy |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Extended Zoptymalizuje Twoje procesy dzięki innowacyjnym technologiom |
Poziom zaawansowania
|
Prostota obsługi
|
Segment Xpert Sprosta Twoim najbardziej wymagającym pomiarom |
Poziom zaawansowania
|
Prostota obsługi
Zależna od urządzenia |
-
-
Instrukcja obsługi (BA)
MCS300P
Multicomponent Analysis System
EN PL 01/01/2025Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
5.5 MB
Nazwa pliku:
8029888_YNV1_OI_MCS300P_en_V1-4_2015-09_EHS.pdf
-
-
-
Rozwiązania branżowe (SO)
Chemicals, petrochemicals and refineries – solutions for the chemical processing industry
Endress+Hauser offers a broad product portfolio of continuous gas analyzers using state-of-the-art technologies.
Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
3.1 MB
Nazwa pliku:
8030415_SO_CPR_en_V1-0_2025.01_EHS.pdf
-
-
-
Broszura dot. kompetencji (CP)
Emission Monitoring Solutions – broad instrument portfolio and longstanding experience
An overview brochure about emission monitoring, their measuring
principles and technologies, global requirements and services, a
selection guide and the measuring devices at a glanceJęzyk:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
4.5 MB
Nazwa pliku:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
-
-
-
Broszura nt. innowacji (IN)
Shelter Solutions – Space and protection for measurement and analysis technology
Shelter solutions are primarily used to protect the installed analyzer systems from extreme ambient conditions such as heat, cold,
dust, wind, earthquakes and corrosive or explosive atmospheresJęzyk:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
4.9 MB
Nazwa pliku:
8030010_IN_Shelter_Solutions_en_V1-0_2025.01_EHS.pdf
-
-
-
Broszura nt. innowacji (IN)
MCS300P – Multi component analyzer
The MCS300P is an extractive process photometer for measurement of gaseous or liquid media. It measures IR and VIS active
components with variable measuring ranges from very low (ppm) to high (vol%) concentrations.Język:
Angielski
Wersja:
01/01/2025
Rozmiar pliku:
2.7 MB
Nazwa pliku:
8029996_IN_MCS300P_en_V3-0_2025.01_EHS.pdf
-
-
-
Plik DTM do weryfikacji
MCS300P HW SDD file
SOPAS device description file for MCS300P HW
Język:
Language neutral
Wersja:
13/04/2018
Rozmiar pliku:
16 MB
Nazwa pliku:
MCS300P HW SDD file
-